Holding Force
UA-Lock-Magnetic-270kg: 270 kg (600 lb)
UA-Lock-Magnetic-540kg: 540 kg (1,200 lb)
Wiring Connection
Connect below terminals to UA-Hub:
Lock 12V/NC (connect to Power Lock Relay NC on UA-Hub)
Lock 12V/COM (connect to Powered Lock Relay COM on UA-Hub)
DPS/+ (DPS+ on UA-Hub)
DPS/-(DPS-onUA-Hub)
Current Power
UA-Lock-Magnetic-270kg: 800mA ±10%
UA-Lock-Magnetic-540kg: 500mA ±10%
Supported Voltage Range
12V DC
Compatibility
UA-Lock-Magnetic-270kg: wooden/metal/glass door
UA-Lock-Magnetic-540kg: wood/metal door
Mounting Accessories
UA-Lock-Magnetic-270kg
L bracket : door thickness < 42 mm (< 1.7"), outward opening door
Z bracket: used with L bracket for inward opening door
U bracket: used with glass door, door thickness ≤ 17 mm; (0.7"); door gap ≤ 5 mm (0.2")
UA-Lock-Magnetic-540kg
L bracket: door thickness < 42 mm (< 1.7"), outward opening door
Z bracket: used with L bracket for inward opening door
LEDs
Green: unlocked
Red: locked
Ambient Operating Temperature
-10 to 50° C (14 to 122° F)
Ambient Operating Humidity
5 to 90% noncondensing
Certifications
FCC, IC, CE