Digital Input
(2) Third-party Wiegand Reader / UniFi Retrofit Reader
(2) Door exit request
(2) Door position
(1) Emergency
Dry Output Relay
Lock: rated 30V DC, up to 1A
Aux: rated 30V DC, up to 1A
Powered Output Relay
12V Lock: 12V DC, up to 1A
24V Lock: 24V DC, up to 0.5A
Ambient Operating Temperature
-10 to 40° C
(14 to 104° F)
Ambient Operating Humidity
Networking Interface
(2) 10/100 MbE RJ45 ports
Buttons
(1) Factory reset
(2) 12V/Dry/24V switch
Recommend Max. Cable Length
UA-Retrofit-Reader (250mA) 18 UACC-Cable-DoorLockRelay length: 152.4 m (500 ft)
24 AWG length: 25 m (82 ft)
22 AWG length: 42 m (138 ft)
20 AWG length: 66 m (217 ft)
18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA) 24 AWG length: 20 m (66 ft)
22 AWG length: 32 m (105 ft)
20 AWG length: 51 m (167 ft)
18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UA-Lock-Magnetic-270kg (800mA) 24 AWG length: 12 m (39 ft)
22 AWG length: 20 m (66 ft)
20 AWG length: 30 m (98 ft)
18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
24 AWG length: 9 m (30 ft)
22 AWG length: 15 m (49 ft)
20 AWG length: 24 m (79 ft)
18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
PoE Cabling Requirements
Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 Statement
Compliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
Certifications
CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision level