Ambient Operating Temperature
0 to 40° C
(32 to 104° F)
Ambient Operating Humidity
PoE Interface
(1) PoE++ input, 50V DC, 1A
(2) PoE+ outputs, 50V DC, 30W per port
(Max 45W aggregated)
Max. Power Consumption
19W (Without PoE output)
50W (With PoE output)
Buttons
(1) Factory reset
(1) Dry/Wet switch
Recommend Max. Cable Length
24 AWG length: 25 m (82 ft)
22 AWG length: 42 m (138 ft)
20 AWG length: 66 m (217 ft)
18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA) 24 AWG length: 12 m (39 ft)
22 AWG length: 20 m (66 ft)
20 AWG length: 30 m (98 ft)
18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
UA-Lock-Magnetic-270kg (800mA) 24 AWG length: 12 m (39 ft)
22 AWG length: 20 m (66 ft)
20 AWG length: 30 m (98 ft)
18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
24 AWG length: 9 m (30 ft)
22 AWG length: 15 m (49 ft)
20 AWG length: 24 m (79 ft)
18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
PoE Cabling Requirements
Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 Statement
Compliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
Certifications
CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision level