UniFi
UISP
Branding
G2 Reader Pro
G2 Reader Pro

UA-G2-Pro

Datasheet
In The Box
Marketing Images
Installation Guide
G2 Reader Pro
G2 Reader Pro
G2 Reader Pro
Mechanical
Dimensions160 x 40.4 x 40.55 mm (6.3 x 1.59 x 1.6")
Weight136 g (4.8 oz)
Enclosure materialPolycarbonate, glass
Mount materialAluminum alloy
MountingWall, gang box
WeatherproofingIP55
Hardware
Networking interface(1) GbE RJ45 port
ConnectivityBLE 4.2
NFC
Power methodPoE
UL 294 Power-limited Class 2 PSU
UL 60950-1/62368-1 LPS/PS2 PSU
Supported voltage range48V DC
Max. power consumption6W
ESD/EMP protectionAir: ±15kV, contact: ±8kV
SensorProximity sensor
Camera view angleH: 96.67°, V: 123.15°, D: 153.11°
MicrophoneYes
Speaker(1) 4 ohm, 1.5W
LEDsR/G/B/W/Amber (Learn more)
Button(1) Factory-reset
NFC frequency13.56 MHz
NFC read range< 30 mm
NFC technologyISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340)
MIFARE Classic / MIFARE DESFIRE
Sony FeliCa™ (ID only)
NFC Forum tags T1T, T2T, T3T, T4T and T5T
Operating environmentOutdoor use
Ambient operating temperatureDevice: -30 to 45° C (-22 to 113° F)
Display:* -10 to 45° C (14 to 113° F)
*The display will turn off when the ambient temperature is above/below the display operation temperature, but other functions will remain functional. (Effective after firmware v1.3.28)
Ambient operating humidity5 to 90% noncondensing
Software informationThe software version of a product can be checked at https://unifi.ui.com
UL 294 levelDestructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level I
UL 294 statementCompliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
PoE cabling requirementsCat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords; 24 AWG (0.21 mm 2 ) for horizontal or riser cable.
CAN/ULC-60839-11-1 GradeGrade assignment: I
CertificationsCE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision levelUA-G2-Pro/UA-G2-Pro-Black, V02
Software
Management applicationUniFi Access: Version 1.5.9 and later