Enterprise Access Hub
Enterprise Access Hub

EAH-8

Datasheet
In The Box
Marketing Images
Installation Guide
Enterprise Access Hub
Enterprise Access Hub
Enterprise Access Hub
Dimensions
379 x 355 x 105 mm (15 x 14 x 4.1")
Supported Doors
8
Input Terminals
(8) Door exit request (8) Door position (1) Emergency
Power Method
Universal input, 100–240V AC, Max. 4.4A, 50/60 Hz 32–48V DC Lead Acid Battery, Max. 7.5A @32V
NDAA Compliant
UL 294 Level
Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I
Weight
Device: 9.1 kg (20 lb) Mount: 624 g (1.4 lb)
Enclosure Material
SGCC steel housing with polycarbonate cover
Mount Material
SGCC steel
Mounting
Wall
Digital Input
(8) Inputs for request-to-exit devices (8) Inputs for door position sensors (1) Emergency
Dry Output Relay
(8) Lock terminals (12V or Dry) (4) AUX terminals for advanced setup (Chime/Siren/Door opener)
Powered Output Relay
Lock: 12V DC, 1A/ Dry Aux: Dry only
Indoor and Outdoor Use
Indoor only
Ambient Operating Temperature
0 to 40° C (32 to 104° F)
Ambient Operating Humidity
5 to 95% noncondensing
Networking Interface
(10) 10/100/1000 Base-T
PoE Interface
(8) PoE
Total Available PoE
60W
Power Supply
AC/DC, internal
Max. Power Consumption
240W
Max. PoE Wattage per Port
15.4W
LEDs
Buttons
(1) Factory-reset
Recommend Max. Cable Length
UA-Lock-Electric (400mA)
24 AWG length: 25 m (82 ft) 22 AWG length: 42 m (138 ft) 20 AWG length: 66 m (217 ft) 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA)
24 AWG length: 20 m (66 ft) 22 AWG length: 32 m (105 ft) 20 AWG length: 51 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UA-Lock-Magnetic-270kg (800mA)
24 AWG length: 12 m (29 ft) 22 AWG length: 20 m (98 ft) 20 AWG length: 30 m (167 ft) 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Other locks (1A)
24 AWG length: 9 m (30 ft) 22 AWG length: 15 m (49 ft) 20 AWG length: 24 m (79 ft) 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
PoE Cabling Requirements
Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 Statement
Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 Grade
Grade assignment: I
Certifications
CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision level
EAH-8, Ver 01
Management Application
Access
Software Information
The software version can be checked at https://unifi.ui.com